trinity-users@lists.pearsoncomputing.net

Message: previous - next
Month: March 2018

Re: [trinity-users] "Start Job"

From: Baron <baron@...>
Date: Fri, 16 Mar 2018 20:45:08 +0000
Hi Guys,

A quick run of "smartctl /dev/sda -a"  gives me no errors.
Log follows:-

=== START OF INFORMATION SECTION ===
Model Family:     Maxtor DiamondMax 10 (SATA/300)
Device Model:     Maxtor 6V200E0
Serial Number:    V40KPSSG
LU WWN Device Id: 0 150500 7da7feb4f
Firmware Version: VA111630
User Capacity:    203,928,109,056 bytes [203 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-7 T13/1532D revision 0
Local Time is:    Fri Mar 16 20:22:57 2018 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

I thought that this disk was 500Gb, it says above 203Gb, or is that 
value the used space.  It shows 458Gb + 25Gb in "My Computer"
It also shows the 458Gb partition as sdf1.  

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection 
activity
                                        was never started.
                                        Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                        without error or no self-test 
has ever
                                        been run.
Total time to complete Offline
data collection:                ( 4622) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline 
immediate.
                                        Auto Offline data collection 
on/off support.
                                        Suspend Offline collection 
upon new
                                        command.
                                        Offline surface scan 
supported.
                                        Self-test supported.
                                        No Conveyance Self-test 
supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before 
entering
                                        power-saving mode.
                                        Supports SMART auto save 
timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging 
supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  90) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 32
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      
UPDATED  WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0027   208   208   063    Pre-fail  
Always       -       13404
  4 Start_Stop_Count        0x0032   253   253   000    Old_age   
Always       -       75
  5 Reallocated_Sector_Ct   0x0033   253   253   063    Pre-fail  
Always       -       0
  7 Seek_Error_Rate         0x000a   253   211   000    Old_age   
Always       -       0
  8 Seek_Time_Performance   0x0027   251   240   187    Pre-fail  
Always       -       54359
  9 Power_On_Hours          0x0032   251   251   000    Old_age   
Always       -       718
 10 Spin_Retry_Count        0x002b   253   252   157    Pre-fail  
Always       -       0
 11 Calibration_Retry_Count 0x002b   253   252   223    Pre-fail  
Always       -       0
 12 Power_Cycle_Count       0x0032   252   252   000    Old_age   
Always       -       648
189 High_Fly_Writes         0x003a   100   100   000    Old_age   
Always       -       0
190 Airflow_Temperature_Cel 0x0022   060   060   000    Old_age   
Always       -       40 (Min/Max 13/40)
192 Power-Off_Retract_Count 0x0032   253   253   000    Old_age   
Always       -       0
193 Load_Cycle_Count        0x0032   253   253   000    Old_age   
Always       -       0
194 Temperature_Celsius     0x0032   034   253   000    Old_age   
Always       -       40
195 Hardware_ECC_Recovered  0x000a   253   252   000    Old_age   
Always       -       1132
196 Reallocated_Event_Count 0x0008   253   253   000    Old_age   
Offline      -       0
197 Current_Pending_Sector  0x0008   253   253   000    Old_age   
Offline      -       0
198 Offline_Uncorrectable   0x0008   253   253   000    Old_age   
Offline      -       0
199 UDMA_CRC_Error_Count    0x0008   199   199   000    Old_age   
Offline      -       0
200 Multi_Zone_Error_Rate   0x000a   253   252   000    Old_age   
Always       -       0
201 Soft_Read_Error_Rate    0x000a   253   252   000    Old_age   
Always       -       0
202 Data_Address_Mark_Errs  0x000a   253   252   000    Old_age   
Always       -       0
203 Run_Out_Cancel          0x000b   253   252   180    Pre-fail  
Always       -       0
204 Soft_ECC_Correction     0x000a   253   252   000    Old_age   
Always       -       0
205 Thermal_Asperity_Rate   0x000a   253   252   000    Old_age   
Always       -       0
207 Spin_High_Current       0x002a   253   252   000    Old_age   
Always       -       0
208 Spin_Buzz               0x002a   253   252   000    Old_age   
Always       -       0
210 Unknown_Attribute       0x0032   253   252   000    Old_age   
Always       -       0
211 Unknown_Attribute       0x0032   253   252   000    Old_age   
Always       -       0
212 Unknown_Attribute       0x0032   253   252   000    Old_age   
Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute 
delay.

-- 
Best Regards:
            Baron